ORDER CODES:
ELVDT - |
G02 - |
H |
5 |
20 |
Model
Name |
Thread
Connection |
Action
Mode |
Relieve
Position Flow Path |
Rated
Flow |
ELVDT |
G02
: 1/4" |
H
: Spring Biased Type |
5
: All Ports Closed |
10 : 10 l/min 20 : 20 l/min 35 : 40 l/min Pressure Drop 7MPa (71kgf/cm2 ) |
SPECIFICATION:
Model |
ELVDT-G02-H510 |
ELVDT-G02-H520 |
ELVDT-G02-H535 |
|
Max.
Operational Pressure |
32
MPa (327 kgf/cm2) |
|||
Allowable
Back Pressure of T Port |
2.5
MPa (25.5 kgf/cm2) |
|||
Rated
Flow ( Pressure Drop 7MPa
(71kgf/cm2) ) |
10
l/min |
20
l/min |
40
l/min |
|
Max.
Operational Flow |
22
l/min |
35
l/min |
50
l/min |
|
Max.
Pressrue Drop |
32
MPa (327 kgf/cm2) |
21MPa (214 kgf/cm2) |
14
MPa (143 kgf/cm2) |
|
Magnetic
Hysteresis |
<
0.5% |
|||
Step
Response ms (0→100% Displacement) |
<
16 ms * |
|||
Frequency
Response Hz (90° Phase Delay ±10% Displacement) |
>
80 Hz |
|||
Center
Drift |
Supply
Pressure |
<
0.5% / FS (∆p=25 MPa) |
||
Fluid
Temperature |
<
1.5% / FS (∆T=40°C) |
|||
Filtration
Finenes |
NAS9級以內 |
|||
Operating
Fluid Temperature Range / Recommended
Fluid Temperature Range |
30~60°C |
|||
Waterproof |
IP53 |
|||
Weight |
2.3
kg |
* Note: Step response is typical value for a supply
pressure of 7MPa (71kgf/cm2) and uid temperature of 40°C (kinematic viscosity:
40mm2/s).
HANDLING:
1. The amplifier and valve have been
adjusted to match at the factory.
2. Install
position: Horizontal.
3. In the case of 3-port applications
and for the direction that throughflow is most common, use of the following
flow is recommended P→A→B→T.
P→A limit differentialpressure is greater than
that of P→B.
4. Be sure to perform sufficient
flushing before a testing run.
5. Use steel piping for this valve and
the main actuator, and keep piping as shortas possible.
6. There is no air bleeding.
7. Mineral oil hydraulic operating fluid
isstandard. Use an R&O type and wearresistant type of ISO VG32, 46, or 68
or equivalent.
8. Cleanness
of the operating Oil should be apply to Nas 9 or cleaner level.
9. Electrical
wiring between the amp and valve should be no longer than 30 meters. For the
solenoid valve use VCTF 2mm2 2-conductor shielded wire, and for the
differential transformer use VCTF 0.5mm2 4-conductor shielded wire.
10. After
disassembling the valve, be sure to fill the inside of the guide with
operatingfluid before reassembling. Tightening Torque : 5 to 7N · m (51 to
71kgf · cm)